Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Acta Odontol Latinoam ; 33(1): 22-26, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32621595

RESUMO

Cone Beam Computed Tomography (CBCT) has modified the perspective of dentistry images, providing manipulable threedimensional images with a 1:1 patient:image ratio. Treatments and diagnosis are modified or corroborated by CBCT; however, its accuracy in thin structures such as cortical bone has been subjected to critical review. The aim of this study is to correlate the measurement of vestibular alveolar bone height using direct measurements and measurements performed with cone-beam tomographic images with standard (SD) voxel resolution. Thirty incisor and premolar teeth of patients undergoing open curettage were measured with a high-precision caliper and with Cone Beam Computed Tomography (CBCT) at an SD resolution of 0.16 mm voxels in a 3D Orthophos XG Sirona scanner. Intra-observer evaluation was performed using the intraclass correlation coefficient (ICC). Direct measurements and CBCT measurements were correlated using Pearson correlation (PCC). The mean difference between indirect and direct measurements was 3.15 mm. Paired t test and Pearson Correlation coefficient determined that all measurements differed statistically from each other with p<0.05. With the CT scanner and protocol used in this study, CBCT images do not enable accurate evaluation of vestibular alveolar bone height.


La tomografía de haz cónico (CBCT) ha modificado la perspectiva de la imagenología en odontología que brinda una imagen tridimensional manipulable con una relación 1:1, paciente: imagen. Los tratamientos y diagnósticos se ven modificados o corroborados por el CBCT; sin embargo, la exactitud que presenta en estructuras delgadas como las corticales óseas ha sido sometida a críticas. El objetivo fue correlacionar la medición de la altura del hueso alveolar vestibular mediante mediciones directas y las realizadas con imágenes tomográficas de haz cónico con resolución de vóxel estándar (SD). Treinta dientes incisivos y premolares de pacientes sometidos a un curetaje abierto se midieron con un calibrador de alta precisión y una tomografía computarizada de haz cónico (CBCT) a una resolución SD de 0,16 mm de vóxeles en un escáner 3D Orthophos XG Sirona. La evaluación intraobservador se realizó utilizando el coeficiente de correlación intraclase (ICC), y las mediciones directas y las mediciones CBCT se correlacionaron utilizando la correlación de Pearson (PCC). La diferencia media entre las mediciones indirectas y directas fue de 3,15 mm. La prueba t pareada y el Coeficiente de Correlación de Pearson determinaron que todas las mediciones fueron estadísticamente diferentes entre sí con una p <0.05. Con el escáner de TC y el protocolo utilizado en este estudio, las imágenes CBCT no permiten una evaluación precisa de la altura del hueso alveolar vestibular.


Assuntos
Processo Alveolar/diagnóstico por imagem , Dente Pré-Molar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/normas , Incisivo/diagnóstico por imagem , Processo Alveolar/anatomia & histologia , Dente Pré-Molar/anatomia & histologia , Tomografia Computadorizada de Feixe Cônico/métodos , Precisão da Medição Dimensional , Humanos , Incisivo/anatomia & histologia , Reprodutibilidade dos Testes
2.
Acta odontol. latinoam ; 33(1): 22-26, June 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1130728

RESUMO

ABSTRACT Cone Beam Computed Tomography (CBCT) has modified the perspective of dentistry images, providing manipulable threedimensional images with a 1:1 patient:image ratio. Treatments and diagnosis are modified or corroborated by CBCT; however, its accuracy in thin structures such as cortical bone has been subjected to critical review. The aim of this study is to correlate the measurement of vestibular alveolar bone height using direct measurements and measurements performed with conebeam tomographic images with standard (SD) voxel resolution. Thirty incisor and premolar teeth of patients undergoing open curettage were measured with a highprecision caliper and with Cone Beam Computed Tomography (CBCT) at an SD resolution of 0.16 mm voxels in a 3D Orthophos XG Sirona scanner. Intraobserver evaluation was performed using the intraclass correlation coefficient (ICC). Direct measurements and CBCT measurements were correlated using Pearson correlation (PCC). The mean difference between indirect and direct measurements was 3.15 mm. Paired t test and Pearson Correlation coefficient determined that all measurements differed statistically from each other with p<0.05. With the CT scanner and protocol used in this study, CBCT images do not enable accurate evaluation of vestibular alveolar bone height.


RESUMEN La tomografía de haz cónico (CBCT) ha modificado la perspectiva de la imagenología en odontología que brinda una imagen tridimensional manipulable con una relación 1:1, paciente: imagen. Los tratamientos y diagnósticos se ven modificados o corroborados por el CBCT; sin embargo, la exactitud que presenta en estructuras delgadas como las corticales óseas ha sido sometida a críticas. El objetivo fue correlacionar la medición de la altura del hueso alveolar vestibular mediante mediciones directas y las realizadas con imágenes tomográficas de haz cónico con resolución de vóxel estándar (SD). Treinta dientes incisivos y premolares de pacientes sometidos a un curetaje abierto se midieron con un calibrador de alta precisión y una tomografía computarizada de haz cónico (CBCT) a una resolución SD de 0,16 mm de vóxeles en un escáner 3D Orthophos XG Sirona. La evaluación intraobservador se realizó utilizando el coeficiente de correlación intraclase (ICC), y las mediciones directas y las mediciones CBCT se correlacionaron utilizando la correlación de Pearson (PCC). La diferencia media entre las mediciones indirectas y directas fue de 3,15 mm. La prueba t pareada y el Coeficiente de Correlación de Pearson determinaron que todas las mediciones fueron estadísticamente diferentes entre sí con una p <0.05. Con el escáner de TC y el protocolo utilizado en este estudio, las imágenes CBCT no permiten una evaluación precisa de la altura del hueso alveolar vestibular.


Assuntos
Humanos , Dente Pré-Molar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/normas , Processo Alveolar/diagnóstico por imagem , Incisivo/diagnóstico por imagem , Dente Pré-Molar/anatomia & histologia , Reprodutibilidade dos Testes , Tomografia Computadorizada de Feixe Cônico/métodos , Processo Alveolar/anatomia & histologia , Precisão da Medição Dimensional , Incisivo/anatomia & histologia
3.
Cranio ; 37(5): 290-295, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29532747

RESUMO

Objective To analyze the association between mandibular vertical asymmetry and the presence of TMD in adult patients. Methods This case-control study recruited patients from the orthodontic clinic at FEBUAP. Patients were classified on the basis of diagnostic criteria for temporomandibular disorders (DC/TMD). Panoramic radiographs were measured to determine mandibular vertical asymmetry indices according to criteria described by Kjellberg and Habets. Both methods (DC/TMD and index criteria) were standardized a priori. Results A total of 56 patients were analyzed, of whom 25 (44.6%) met the inclusion criteria and were divided into two groups (TMD group, n = 15; non-TMD group, n = 10). The highest asymmetry index was observed in the condylar neck, followed by the total condylar asymmetry index, but without significant differences between groups (p > .05). Conclusion There is no association (p > .05) between temporomandibular disorders and mandibular vertical asymmetry.


Assuntos
Côndilo Mandibular , Transtornos da Articulação Temporomandibular , Adulto , Estudos de Casos e Controles , Humanos , Mandíbula , Radiografia Panorâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...